Specification
The performance of LT is shown in the table below.
LT・・・CE performance
| Item | Model and size | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| LT100CEG | LT150CEG | LT150CETF | ||||||||
| Maximum thrust(1) | N | 120 | 350 | 390 | ||||||
| Rated thrust | N | 15 | 60 | 70 | ||||||
| Maximum load mass | Kg | 12 | 35 | 39 | ||||||
| Resolution | μm | 0.1 | 0.5 | 1.0 | 0.1 | 0.5 | 1.0 | 0.1 | 0.5 | 1.0 |
| Maximum speed(2) | mm/s | 690 | 2000 | 2000 | 700 | 2000 | 2000 | 700 | 2000 | 2000 |
| Positioning repeatability(3) | μm | ±0.5 | ±0.5 | ±1.0 | ±0.5 | ±0.5 | ±1.0 | ±0.5 | ±0.5 | ±1.0 |
| Notes(1) | The duration of maximum thrust is up to 1 second. |
| (2) | This maximum speed may not be reached depending on the maximum output frequency of the controller used, and the driver type or settings. |
| (3) | When the temperature of the product is constant. |
LT・・・LD performance
| Item | Model and size | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LT130LDG | LT170LDG | LT170LDV | LT170LDTF | ||||||||||
| Maximum thrust(1) | N | 120 | 350 | 145 | 390 | ||||||||
| Rated thrust | N | 15 | 60 | 25 | 70 | ||||||||
| Maximum load mass | Kg | 12 | 35 | 20 | 39 | ||||||||
| Resolution | μm | 0.1 | 0.5 | 1.0 | 0.1 | 0.5 | 1.0 | 0.1 | 0.5 | 1.0 | 0.1 | 0.5 | 1.0 |
| Maximum speed(2) | mm/s | 690 | 2000 | 3000 | 700 | 2000 | 2000 | 700 | 2000 | 3000 | 700 | 2000 | 2000 |
| Positioning repeatability(3) | μm | ±0.5 | ±0.5 | ±1.0 | ±0.5 | ±0.5 | ±1.0 | ±0.5 | ±0.5 | ±1.0 | ±0.5 | ±0.5 | ±1.0 |
| Notes(1) | The duration of maximum thrust is up to 1 second. |
| (2) | This maximum speed may not be reached depending on the maximum output frequency of the controller used, and the driver type or settings |
| (3) | When the temperature of the product is constant. |
LT・・・H and LT・・・H2 performance
| Item | Model and size | |||||||
|---|---|---|---|---|---|---|---|---|
| LT170H | LT170H2 | |||||||
| Maximum thrust(1) | N | 900 | 500 | |||||
| Rated thrust(2) |
Natural air cooling | N | 120 | 260 | ||||
| Air cooling(3) | N | 150 | ー | |||||
| Maximum load mass | Kg | 90 | 40 | |||||
| Resolution | μm | 0.1 | 0.5 | 1.0 | 0.1 | 0.5 | 1.0 | |
| Maximum speed(4)(5) | mm/s | 690 | 1500(2000) | 1500(2000) | 690 | 3000 | 3000 | |
| Positioning repeatability(6) | μm | ±0.5 | ±0.5 | ±1.0 | ±0.5 | ±0.5 | ±1.0 | |
| Notes(1) | The duration of maximum thrust is up to 1 second. |
| (2) | In the case where the unit is fixed on a steel-made cradle under ambient temperature of 0 to 25℃. For more information, please see Product Catalogue. |
| (3) | This is under air flow rate of 30NL/min. |
| (4) | For the speed exceeding 1,500mm/s, please contact IKO. |
| (5) | This maximum speed may not be reached depending on the maximum output frequency of the controller used, and the driver type or settings. |
| (6) | When the temperature of the product is constant. |
Some products are not shown in the catalogue. Also, modifications can be made to meet your requirements. Please do not hesitate to make inquiries.